Expand description
First-principles science oracle validation (energy conservation, Stokes-Mueller, calibration).
Independent physical invariant, passivity, conservation, uncertainty, and cross-modal
registration verifiers for the EMF v4 and QAC v1 scientific evolution programme
(Packet N04 — independent_science_reviewer, Gates G-SCIENCE & G-GPU).
All reference expectations in this module hierarchy are evaluated from closed-form
first-principles equations in independent f64 and checked i128 rational arithmetic
without delegating to candidate solver implementations.
§Submodules
- [
stokes_mueller]: Stokes physical realizability (overflow-safe scaled 3D hypot, degree of polarization, non-clamping over-polarization rejection), Jones-to-Mueller exact equivalence, and $4\times 4$ Cloude Hermitian coherency matrix positive-semidefiniteness & passivity. - [
passivity_conservation]: C02-C09 numerical budget evaluators (f64closed-form, $N$-term Higham $\gamma_N$ reduction, QACB32scalar & vector $L_2$), electromagnetic Poynting balance, 3D Cartesian Yee CFL & discrete dispersion, acoustic fluid/elastic/interface conservation, multi-port scattering matrix passivity ($|\mathbf{S}|_2 \le 1$), and grid-refinement convergence order ($p \ge 1.8$). - [
uncertainty_ece]: C02-C05 uncertainty descriptor validation, Gaussian coverage factor $k \leftrightarrow p$ consistency via positive-term Kummer $\operatorname{erf}(k/\sqrt{2})$, one-shot affine calibration idempotence, half-open calibration windows, $3\times 3$ SPD covariance rotation $\mathbf{R}\boldsymbol{\Sigma}\mathbf{R}^T$, Mahalanobis NEES, ECE, Brier score, and Gaussian NLL. - [
specialized_oracles]: Mode0x0106(EMF ionizing radiation Beer-Lambert, independent absorbed dose, $\text{keV}\to\text{J}$, XCOM dose-inference prohibition), Mode0x0107(EMF bioelectric dipole forward potential & singularity/reference guards), Mode0x0106(QAC haptic contact pressure, Hooke restoring force, role/expiry guards), Mode0x0107(QAC ultrasound round-trip ToF, derated Mechanical Index, monostatic Doppler, TI model guard), and C02-C08 I/Q carrier conjugation bridge. - [
cross_modal_registration]: Orderedf64quaternion norm admission, derived orthogonal Hamilton rotations, proper rotation determinant/orthogonality gates, exacti128rational clock synchronization, material0EMF/QAC disambiguation, and.10d/.m64anatomical AABB and surface-normal invariants.
Re-exports§
pub use cross_modal_registration::compose_hamilton_quaternions_xyzw;pub use cross_modal_registration::evaluate_exact_sample_instant;pub use cross_modal_registration::ordered_quaternion_norm_sq;pub use cross_modal_registration::transform_local_to_parent;pub use cross_modal_registration::verify_anatomical_region_registration;pub use cross_modal_registration::verify_and_derive_quaternion_rotation;pub use cross_modal_registration::verify_cross_modal_clock_join;pub use cross_modal_registration::verify_material_and_anatomy_coupling;pub use cross_modal_registration::verify_stationary_proper_rotation_matrix;pub use cross_modal_registration::MaterialDomainFamily;pub use cross_modal_registration::RationalClockDescriptor;pub use cross_modal_registration::RationalSeconds;pub use cross_modal_registration::RegistrationValidationError;pub use cross_modal_registration::VerifiedQuaternionRotation;pub use cross_modal_registration::FRAME_ADMISSION_TOLERANCE;pub use passivity_conservation::evaluate_acoustic_interface_oracle;pub use passivity_conservation::evaluate_em_mode0_instantaneous_oracle;pub use passivity_conservation::evaluate_em_wavelength_m;pub use passivity_conservation::evaluate_qac_elastic_mode01_oracle;pub use passivity_conservation::evaluate_qac_fluid_mode00_oracle;pub use passivity_conservation::gamma_n_f64;pub use passivity_conservation::verify_acoustic_energy_conservation;pub use passivity_conservation::verify_b32_scalar_budget;pub use passivity_conservation::verify_b32_vector_budget;pub use passivity_conservation::verify_f64_closed_form_budget;pub use passivity_conservation::verify_grid_convergence_order;pub use passivity_conservation::verify_n_term_reduction_budget;pub use passivity_conservation::verify_poynting_conservation_balance;pub use passivity_conservation::verify_scattering_matrix_passivity;pub use passivity_conservation::verify_yee_cfl_and_dispersion;pub use passivity_conservation::BudgetEvaluation;pub use passivity_conservation::ConservationValidationError;pub use passivity_conservation::EmMode0OracleResult;pub use passivity_conservation::QacElasticMode01OracleResult;pub use passivity_conservation::QacFluidMode00OracleResult;pub use passivity_conservation::C02_AMPLITUDE_SCALES_B32;pub use passivity_conservation::C02_AMPLITUDE_SCALES_F64;pub use passivity_conservation::F32_UNIT_ROUNDOFF;pub use passivity_conservation::F64_EPSILON;pub use passivity_conservation::F64_UNIT_ROUNDOFF;pub use passivity_conservation::VACUUM_IMPEDANCE_OHM;pub use passivity_conservation::VACUUM_PERMEABILITY_H_PER_M;pub use passivity_conservation::VACUUM_PERMITTIVITY_F_PER_M;pub use specialized_oracles::convert_and_verify_iq_carrier_bridge;pub use specialized_oracles::convert_kev_to_joules;pub use specialized_oracles::convert_mw_per_cm2_to_w_per_m2;pub use specialized_oracles::convert_spectral_density_hz_to_wavelength_m;pub use specialized_oracles::evaluate_absorbed_dose_gy;pub use specialized_oracles::evaluate_bioelectric_dipole_potential_v;pub use specialized_oracles::evaluate_equivalent_dose_sv;pub use specialized_oracles::evaluate_haptic_mechanical_oracle;pub use specialized_oracles::evaluate_ionizing_beer_lambert_oracle;pub use specialized_oracles::evaluate_qac_db_spl_oracle;pub use specialized_oracles::evaluate_qac_modal_oscillator_oracle;pub use specialized_oracles::evaluate_ultrasound_mode07_oracle;pub use specialized_oracles::reconstruct_emf_negative_carrier_rf;pub use specialized_oracles::reconstruct_qac_positive_carrier_rf;pub use specialized_oracles::HapticMechanicalOracleResult;pub use specialized_oracles::HapticRole;pub use specialized_oracles::IonizingRadiationOracleResult;pub use specialized_oracles::SpecializedOracleError;pub use specialized_oracles::UltrasoundOracleResult;pub use specialized_oracles::ELEMENTARY_CHARGE_J_PER_EV;pub use stokes_mueller::apply_mueller_matrix;pub use stokes_mueller::compute_cloude_coherency_matrix;pub use stokes_mueller::deterministic_transverse_basis;pub use stokes_mueller::hermitian_4x4_eigenvalues;pub use stokes_mueller::jones_to_mueller_matrix;pub use stokes_mueller::jones_vector_to_stokes;pub use stokes_mueller::rotate_stokes_transverse_basis;pub use stokes_mueller::scaled_hypot3;pub use stokes_mueller::vacuum_or_homogeneous_propagation_delay_s;pub use stokes_mueller::verify_jones_to_mueller_equivalence;pub use stokes_mueller::verify_mueller_realizability;pub use stokes_mueller::verify_stokes_realizability;pub use stokes_mueller::Complex64;pub use stokes_mueller::PolarimetricValidationError;pub use stokes_mueller::VerifiedMuellerReport;pub use stokes_mueller::VerifiedStokesState;pub use stokes_mueller::C02_ROUNDING_FACTOR;pub use stokes_mueller::F64_EPS;pub use stokes_mueller::VACUUM_SPEED_OF_LIGHT_M_PER_S;pub use uncertainty_ece::apply_or_verify_affine_calibration;pub use uncertainty_ece::erf_f64;pub use uncertainty_ece::evaluate_ece_and_brier;pub use uncertainty_ece::evaluate_gaussian_nll;pub use uncertainty_ece::gaussian_coverage_probability;pub use uncertainty_ece::mahalanobis_nees_3d;pub use uncertainty_ece::rotate_covariance_3x3;pub use uncertainty_ece::verify_covariance_3x3_spd;pub use uncertainty_ece::verify_gaussian_coverage_factor;pub use uncertainty_ece::verify_half_open_calibration_window;pub use uncertainty_ece::verify_uncertainty_descriptor;pub use uncertainty_ece::CalibrationMetricsReport;pub use uncertainty_ece::CalibrationStage;pub use uncertainty_ece::UncertaintyDescriptor;pub use uncertainty_ece::UncertaintyKind;pub use uncertainty_ece::UncertaintyValidationError;
Modules§
- cross_
modal_ registration - Cross-modal EMF v4, QAC v1, and anatomical
.10d/.m64coordinate frame, rational clock, and material/anatomy registration invariant verifiers (C02-C03, C02-C04, C02-C06). - passivity_
conservation - Passivity, energy conservation, and C02-C09 numerical budget verifiers.
- specialized_
oracles - Specialized independent physics oracles for EMF Modes 3, 5, 6, 7 and QAC Modes 04, 05, 06, 07, plus the C02-C08 cross-domain I/Q carrier convention bridge.
- stokes_
mueller - Stokes vector and Mueller $4\times 4$ matrix polarimetric realizability verifiers (C02 Mode 1 & Mode 4).
- uncertainty_
ece - Uncertainty calibration, Gaussian coverage factor, covariance rotation, Mahalanobis NEES, and Expected Calibration Error (ECE) verifiers (C02-C03, C02-C04, C02-C05, Modes 6 & 7).
Functions§
- run_
all_ science_ validations - Execute a consolidated reference validation pass across all five
N04submodules (stokes_mueller,passivity_conservation,uncertainty_ece,specialized_oracles, andcross_modal_registration).