Expand description
Source-bound patient-space (DICOM LPS mm) to anatomical/target coordinate frame
registration with FrameOfReferenceUID verification, SO(3) / affine invertibility,
roundtrip consistency enforcement, and distinct BLAKE3 derivation stamps.
Structs§
- Cross
Frame Registration Certificate - Nricp
Registration Result - Output of
register_stiffness_penalized_surfacewith per-vertex affine fields and residuals. - Registered
Anatomy Point - Stiffness
Penalized Nricp Config - Configuration for stiffness-penalized locally affine Non-Rigid ICP (Amberg et al. 2007)
weighted by per-vertex cortical BMD stiffness
E(rho_app)and observation confidencew_k = c_obs(t).
Enums§
Constants§
- REF_
CORTICAL_ MODULUS_ GPA - Canonical cortical bone elastic modulus reference (GPa) at
rho_app = 1.85 g/cm^3.
Functions§
- cortical_
bmd_ stiffness_ gpa - Compute cortical/trabecular bone mineral stiffness
E(rho_app)in GPa via Carter-Hayes / Morgan-Keaveny power-law scaling for NRICP regularization weights. - register_
patient_ to_ anatomy - Register image pixel
(col, row)throughPatientImagePlaneand a verifiedSO(3)/ affine anatomical transform, refusing missing or mismatchedFrameOfReferenceUIDwithout a certificate. - register_
stiffness_ penalized_ surface - Stiffness-penalized locally affine Non-Rigid ICP surface registration incorporating
cortical BMD stiffness weights
E(rho_app)and temporal observation confidence weightsc_obs(t).