Room Acoustics: Sabine / Eyring-Norris / Millington-Sette $T_{60}$ & Schroeder RIR Integration Facade.
Re-exports the canonical Sabine, Eyring-Norris, and Millington-Sette $T_{60}$ reverberation
time calculators and ISO 3382-1 Schroeder backward integration ($\text{EDT}, T_{20}, T_{30},
C_{50}, C_{80}, D_{50}, T_s$) from [etalon_sim::acoustics_continuum::room_acoustics].
Structs§
- RirAcoustics
Report - Complete ISO 3382-1 room impulse response (RIR) decay and clarity analysis.
- Room
Geometry - Room geometry and acoustic boundary model for $T_{60}$ calculations.
- Surface
Patch - Surface patch with area $S_i$ ($\text{m}^2$) and random-incidence absorption coefficient $\alpha_i$.
Constants§
- RT60_
NUMERATOR_ 55_ 25 - Canonical numerator constant $55.25 = \frac{60 \times 4}{\ln(10)^{-1}} \approx 24\ln(10)$ used in the Sabine/Eyring/Millington formulas.
- RT60_
NUMERATOR_ EXACT_ 24LN10 - Exact theoretical numerator $24\ln(10) \approx 55.2620422318571$.
Functions§
- analyze_
room_ impulse_ response - Perform full ISO 3382-1 analysis on a discrete room impulse response $h[n]$ sampled at
sample_rate_hz. - fit_
decay_ rt60_ s - Fit linear least-squares decay slope on
edc_dbbetweenstart_db(e.g.-5.0) andend_db(e.g.-35.0) and return the extrapolated $-60\text{ dB}$ decay time $T_{60}$ in seconds. - schroeder_
backward_ integration_ db - Compute the normalized Schroeder backward energy integration curve in dB: $$E(k) = \sum_{n=k}^{N-1} h[n]^2, \qquad L_{\text{EDC}}(k) = 10\log_{10}!\left(\frac{E(k)}{E(0)}\right)$$ Rejects empty, non-finite, or all-zero silent impulse responses (C02-C01 / AQ-04).