Room Acoustics: Sabine / Eyring-Norris / Millington-Sette $T_{60}$ & Schroeder RIR Integration Facade.

Re-exports the canonical Sabine, Eyring-Norris, and Millington-Sette $T_{60}$ reverberation time calculators and ISO 3382-1 Schroeder backward integration ($\text{EDT}, T_{20}, T_{30}, C_{50}, C_{80}, D_{50}, T_s$) from [etalon_sim::acoustics_continuum::room_acoustics].

Structs§

RirAcousticsReport
Complete ISO 3382-1 room impulse response (RIR) decay and clarity analysis.
RoomGeometry
Room geometry and acoustic boundary model for $T_{60}$ calculations.
SurfacePatch
Surface patch with area $S_i$ ($\text{m}^2$) and random-incidence absorption coefficient $\alpha_i$.

Constants§

RT60_NUMERATOR_55_25
Canonical numerator constant $55.25 = \frac{60 \times 4}{\ln(10)^{-1}} \approx 24\ln(10)$ used in the Sabine/Eyring/Millington formulas.
RT60_NUMERATOR_EXACT_24LN10
Exact theoretical numerator $24\ln(10) \approx 55.2620422318571$.

Functions§

analyze_room_impulse_response
Perform full ISO 3382-1 analysis on a discrete room impulse response $h[n]$ sampled at sample_rate_hz.
fit_decay_rt60_s
Fit linear least-squares decay slope on edc_db between start_db (e.g. -5.0) and end_db (e.g. -35.0) and return the extrapolated $-60\text{ dB}$ decay time $T_{60}$ in seconds.
schroeder_backward_integration_db